New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Vaillant VR70 S7 Solarpump #330
Comments
what are reasonable values corresponding to those hex values? |
Useful values would be 0 to 6 liters. |
can you check what ebusctl grab decode show for the message, especially in the lines with the EXP data type? |
How can I check that exactly? |
|
Sorry for the late reply, I forgot.
|
how did you get the "c8 50 00" values from your initial post? i.e. is this related to a specific message? |
I received the message "c8 50 00" after activating the sensor value S7 in the file 52.vr_70.csv. Original Changed |
I doubt that the value will consist of 3 bytes. Even if its just 2 bytes, the value range would be 5017 to 50c8 in hex, so 20503-20680 in dec, which is way outside of something in the range 0-6 liters no matter which divider you use. |
Yes that could be true. How can I implement the settings? |
just use UCH as datatype and put 32 in the divisor column behind |
@MatthiasKunze did you get it work? I tried it like John said. If the pump isn't running, 12.5l is displayed. |
Please, can anybody help me with my problem?
|
so you'd just have to add the divisor 32 in the right column of the corresponding field like this:
|
closed due to inactivity |
Hello, the pump for the solar system is connected to connection R1 / S7 on my Vaillant VR70.
With ebusd I get the following data for sensor 7:
I think the data shows the flow of the solar system in liters per minute.
c8 50 00 is the value when the solar pump is off.
Do you have an idea how the data can be converted into liters per minute?
The text was updated successfully, but these errors were encountered: